Introduction

This document is not finalized, if you can provide data and values of other thermal fuses, you can collaborate on the document.

  1. sNgQOPE5OHd1RBjB
    sNgQOPE5OHd1RBjB
    PAOJ1q2hj6KFmGrk
    • This document is a summary of other documents I have already published regarding thermal fuse values for coffee machines. It is a work in progress, so as I gather more values, I will add them. Anyone who wishes can contribute values based on their knowledge or research. Together, we can create a useful database.

    • When replacing a thermal fuse, we must consider both the temperature it can withstand and the current it can handle.

    • NEVER INSTALL A THERMAL FUSE THAT WITHSTANDS LESS TEMPERATURE; always use one with the same or slightly higher rating.

    • NEVER INSTALL A THERMAL FUSE THAT WITHSTANDS LESS CURRENT, as it will overheat easily. Always use one with the same rating; if this parameter is higher, it's even better. The key factor of a thermal fuse is ITS MAXIMUM OPERATING TEMPERATURE.

    • For more information, search on Google: Thermal fuse.

    omdat de temperatuur zo hoog is mag de zekering nooit gesoldeerd worden..

    Fast Eddy -

    Traducido:

    debido a que la temperatura es tan alta, el fusible nunca debe soldarse

    CORRECTO estos fusibles no deben soldarse.

    Carlos López (España - Spain) -

  2. MBpKTrStNI2fQBCn
    MBpKTrStNI2fQBCn
    CPkFSu2kVjHPEUKL
    2ZQIhMXXa1eZBscT
    • The Nescafé Dolce Gusto Krups KP1600 coffee machine has 3 thermal fuses, 2 in the boiler and 1 in the water pump.

    • Two thermal fuses located on the boiler, secured by a metal plate and screw, both have blown.

    • 133º - 10A

    • RELATED DOCUMENT, MORE EXTENSIVE: https://es.ifixit.com/Gu%C3%ADa/CAFETERA...

  3. XGaduyITUkMLpTJR
    XGaduyITUkMLpTJR
    YTVBhZRnyMvU53SJ
    NuaZON333AJv4O3y
    • Nescafé Dolce Gusto Krups KP1600 coffee machine water pump fuse.

    • Located in the body of the water pump, inserted, easy to extract. When the pump is installed, it is barely visible.

    • 113º - 10A

    • As an observation: This fuse rarely blows; the water pump winding is usually damaged first.

  4. Bll4BuyBgaIpTCsv
    Bll4BuyBgaIpTCsv
    eXDQDvbOUSES2LIp
    fJm14NBJo3m1DB3T
    • Nespresso coffee machines, Delonghi, and many similar models.

    • 2 thermal fuses on the boiler, one on each side, secured by a metal plate and screw.

    • 167º - 5 A

  5. pD51yYAOk3Lkbsod
    pD51yYAOk3Lkbsod
    VnSqX2eQdLdk4AJf
    OMWXvQQFphHVMdMm
    • Saeco Via Veneto coffee machine: 1 thermal fuse located on the boiler at the top of the machine.

    • 186º - 5A. In the market, we can find a compatible one rated for 192º.

    • It is a common fault for this model: the machine is dead due to a blown thermal fuse. There are some videos on YouTube about it.

  6. GhLE2PxCaDpZA1Dv
    • NOTE: The replacement of thermal fuses is done with electrician-type terminal blocks, isolating the entire body (NOTE: in the photo, it is still pending isolation). The fuses are crimped at their connection to the wire. If they need to be soldered, there is a technique to prevent damage, by holding them with a wet cloth or an ice cube.

  7. 23Q53sS2JXH4GBwE
    23Q53sS2JXH4GBwE
    HrXbFtFdvhPYGshw
    htILRkfVMHvNUVWF
    • Princess Hot Air Fryer: Thermal Fuse Value AUPO BF172 172º / 10 A / 250V - G1 is located on the metal plate of the heating element, requiring almost complete disassembly. It has 2 fuses enclosed in textile tubes, and usually, one of them blows. This causes the fryer to stop heating and the fan to stop rotating, although the display still turns on.

    • Repair guide: New contribution made 09/07/2023.

  8. xX3A3XuZl1AxGAOL
    xX3A3XuZl1AxGAOL
    Rq2GRIY4oQLM6OeZ
    TEsuWDZbtYtyHWkr
    • Equation DL06 Stand Air Convector, dead, does not turn on.

    • Thermal fuse fault at 157º, replaced with one rated for 192º, slightly moving it away from the support using electrician terminal blocks.

    • Related repair guide

  9. QNjoZMTJFDFU5UWt
  10. bJeRODvQBHsInaKV
    bJeRODvQBHsInaKV
    HPH6TEtQNYcaeQiJ
    QKDCJCdXQQjVKZLN
  11. OGw5aDhYjHfCtlF1
    OGw5aDhYjHfCtlF1
    AT6bDmbjfDW3C6sS
    DL5oA3PZkcP35DQv
    • RIVER PA-4628-A griddle does not heat up or light the thermostat pilot light. 117ºC 16A THERMAL FUSE.

    • TO BE CONTINUED... WHEN I GATHER MORE DATA ON DEVICES WITH THERMAL FUSES, you can contribute to this document by sharing what you have been able to find out about other coffee makers and equipment.

Conclusion

Informative guide under construction

Carlos López (España - Spain)

Member since: 02/07/15

85434 Reputation

7 comments

Hola!

No me parece adecuado sustituir los fusibles quemados por otros de más temperatura. El fabricante estableció una temperatura maxima de seguridad que no permita que se dañen otros componentes, si sustituimos por uno de mayor capacidad, permitirá que el dispositivo se caliente másy se puedan ocasionar daños irreversibles en otras piezas mas costosas o insustituibles. Por otra parte, cambiarlos por otros de menor temperatura de corte, hará que salten en regimen de uso normal.

Arduinoxino -

Hola, Respeto tu opinion, pero por experiencia en numerosas reparaciones, el fusible termico se puede colocar de un valor ligeramente mayor ya que realmente sigue cumpliendo su función, en los aparatos que lo cambiar si tienen sobretemperatura se funde igualmente.

Carlos López (España - Spain) -

¿Puedo cambiar un fusible 172 por uno 192 en una free air?

Fernando Bravo -

Si, realmente son 20 º de diferencia a esa temperatura elevada la proteccion seguira siendo la misma

Carlos López (España - Spain) -

Please tell me how to dissasemble the same model Nespresso/Delonghi coffee maker as you show in your pictures. Or maybe you have a PDSF of the repair manual you could post here. I can not find any instructions or videos showing the removal of the outside panels for that model. It has rivets not screws on the bottom and elsewhere. I need to know if the side panels have plastic clips holding them or those rivets. Also, can you verify this model has a thermal fuse for the pump? Mine starts and lights up correctly when you push the power button, it gets hot but then the pump doesn't start when you push the coffee button. I believe I know how I accidentally overheated it yesterday causing the pump thermalfuse to blow..

Michele Duval -

TRADUCCION

Por favor, indíqueme cómo desmontar la cafetera Nespresso/Delonghi del mismo modelo que se muestra en las imágenes. O tal vez tenga un PDSF del manual de reparación que pueda publicar aquí. No encuentro ninguna instrucción ni vídeo que muestre cómo retirar los paneles exteriores de ese modelo. Tiene remaches en lugar de tornillos en la parte inferior y en otras partes. Necesito saber si los paneles laterales están sujetos con clips de plástico o con esos remaches. Además, ¿puede verificar si este modelo tiene un fusible térmico para la bomba? La mía se enciende y se ilumina correctamente cuando se pulsa el botón de encendido, se calienta, pero luego la bomba no se pone en marcha cuando se pulsa el botón de café. Creo que sé cómo la sobrecalenté accidentalmente ayer, provocando que se fundiera el fusible térmico de la bomba.

Carlos López (España - Spain) -

Por favor anexa unas fotos de tu cafetera para ver que modelo es exactamente anexa una foto de la pegatina infereior que indica el modelo, de nespresso hay bastantes quias pero no todas desmontan o acceden a la bomba . mira aqui Nespresso

Carlos López (España - Spain) -