Introduction

Setting the ECAM models with touch display to test mode is a little tricky. These instructions show you how to do this on the ECAM 350.55, but this guide will also work for other ECAM models, such as the 370.70. You can use the test mode to quickly check the function of the most important components. For models with "real" buttons, see here.

  1. u2GE6jIU4iDSIlUZ
    u2GE6jIU4iDSIlUZ
    TCNuYCAFvbNoHEZn
    gKE56pxYifqME2jj
    • When the machine is switched on, press the off-switch until the machine goes into standby mode and the display turns off.

    • There has to be water in the water tank, the drip tray is initially still inserted. The power plug remains in the outlet.

  2. 3kKaNtcMM1KQQO5r
    3kKaNtcMM1KQQO5r
    jhpEflmqNVscNH6N
    • Pull the drip tray out a little, a corresponding message will appear on the display. (In the picture in English)

  3. 6NnyDTqnFpLH46iy
    6NnyDTqnFpLH46iy
    bLlireO2eXT6lpwB
    Ko1LKcdHeiNSUwjL
    • First press and hold the ESC button, then press and hold the remaining three buttons in the other corners simultaneously.

    • SELECT TEST MODE" will appear on the display. Push the drip tray back in

    • Press the "DRINK MENU" button

  4. 1vLqQ1FPM5BuyFso
    1vLqQ1FPM5BuyFso
    LfqfWuAZarYsRJTa
    1TY4DTd3xbBDa621
    • You can now test various functions:

    • Brew group up/brew group down

    • Ev2 = solenoid valve2 clicks (upper 3-way valve)

    • Ev1 = solenoid valve1 clicks (lower 3-way valve)

    • Grinder is running

    • Coffee heater gets hot

    • Steam heater

    • Pump is running

    How can I find out statistics for a ECAM model 350.50 or 350.15 without a display? thanks

    Дмитрий Кудрявцев -

    Hallo

    Was für Problem hat die dinamyka wenn das Ev2 = Elektroventil2 klickt (oberes 3-Wege-Ventil) nichts hören lässt und Ventil Ev1 nicht mal im Display angezeigt wird oder man was hört?

    Es kommt zwar wieder mal Kaffe, aber beim Spülen (abschalten) fliesst kein Wasser mehr aus dem Kaffe Ausfluss,geht direkt in den Wasser Aufgang Behälter!

    Beim entkalken das gleiche,früher kam zumindest bei Zeit was vorne raus, jetzt geht es nur noch durch heiss Wasser auslass und direkt abtropf Schale rein!

    Sind die 2 Ventile hin oder was?

    Danke für ihre Mühen und die Beschreibungen

    Schmitter Fredy -

    Soweit ich mich erinnere hat die dinamica zwei Elektroventile, beide müssten klicken. Ich würde beide erstmal überprüfen, also den Widerstand der Spule messen, dann die Mechanik aufschrauben und gängig machen. Sie sind auch nicht allzu teuer für einen eventuellen Austausch. So wie sich das anhört, könnte es auch ein verstopfter oberer Kolben sein. Für alles haben wir Anleitungen. Gutes Gelingen!

    VauWeh -

    Welk voordeel heeft deze testmodus inschakeling?

    Brutus.

    Brutus -

    There are other useful menus from here as described in this service manual for a similar model. In particular, I needed to reset the carriage drive encoder after replacing the infuser and thermoblock – the drive mechanism wears and the end limit positions change over time. This is achieved by repeating the above steps, but pressing espresso "☕️" instead of "Drink Menu" when reinserting the dip tray. After this, the machine must be started normally, and a manual rinse performed via the "rinse button" (on my machine, this is a "rinse" menu option behind the settings "⚙️" button).

    Elliot West -

    Hallo

    Ich habe auch das Problem mit der Allgemeinen Störung, das Ventil EV2 klinkte nicht mehr, hat auch keine Spannung von der Platine bekommen, diese habe ich gewechselt

    Die Maschine geht jetzt an und beginnt den Heizvorgang aber dann kommt wieder allgemeine Störung

    Kann noch jemand helfen

    nico_richter90@web.de -

    Hallo und vielen Dank dafür, dadurch konnten wir herausfinden, dass wohl das Ev1 kaputt ist...

    Martina F. -

    Hallo, bei meine 450.86.T eletta explore leuchtet der " Allgemeine Alarm" immer bei kalter Maschine am morgen, oder nach ca. 1 Std. nicht Benutzung. Durch ausschalten und wieder einschalten funktioniert alles ganz normal. Die Maschine hat ca. 120 brüh Vorgänge, habe sie erst 4 Wochen. Ich hoffe mir kann jemand helfen. Danke im voraus, Gruß, Bobby

    Robert Eigner -

    Sehr merkwürdig. Aber wenn die Maschine nagelneu ist würde ich nicht lange nachdenken und die Garantie in Anspruch nehmen.

    VauWeh -

    Hallo, danke für die schnelle Antwort. Werde ich machen, hatte gehofft, das ich es anders hin bekomme. Schönen Sonntag!

    Robert Eigner -

    Does anyone know if the encoder that is being reset is the Hall sensor that counts the revolutions of the transmission? Or is it the machine software? I replaced the Hall sensor, but the machine is still going to the top and getting stuck. The micro switches at the top and bottom test good. So I think a reset is in order, but not sure. Also does anyone have the Test Mode instructions for the ECAM 23260sb? I have searched all over.

    Lisa W -

    See my comment from Aug 31, 2025. You need to recalibrate the encoder - the effective count changes as the transmission wears. It does seem counter intuitive that this is not determined from the limit switches alone.

    Elliot West -

    @lisaw49448 Try these guides/videos for the testmode with your 23260: video and guide, perhaps it will work.

    VauWeh -

Conclusion

Work through the steps in reverse order to reassemble your device.