Elson’s test: bend PIP 90 deg over edge of table, extend middle phalanx against resistance. Should have weak PIP extension and DIP goes rigid as lateral bands have to work.
Positive test indicated rupture of central tendon slip.
If open or with displaced avulsion fracture: operative repair
Closed: splint in extension (Both DIP and PIP) for up to 6 weeks, refer to hand surgeon. NO flexion of DP permitted for duration of splinting, including during cleaning. Repair extensor tendon if injured.
Disposition
Hand specialist follow up if closed injury
Immediate consult if deformity is caused by open injury