Modified positional valsalva
Background
2015 REVERT Trial
Studied modified Valsalva for SVT conversion to normal sinus:[ 1]
Normal Valsalva - 17% resolution
Modified Positional Valsalva - 43% resolution
No adverse events or costs associated with Modified Positional Valsalva
Set-up
10ml syringe with plunger
Two assistants - one to adjust head of bed and another to raise/lower legs.
Steps
Position patient with legs flat and head of bed to 45°
Have patient attempt to blow out plunger of 10ml syringe (or Valsalva around 40mmHg) for 15 seconds
Quickly reposition patient's head of bed to flat and have the other assistant raise legs to 45° for another 15 seconds
Return head of bed to 45° and continue to monitor for resolution for 1 minute
Repeat if needed
External Links
See Also
References
↑ Appelboam A. et al. Postural modification to the standard Valsalva manoeuvre for emergency treatment of supraventricular tachycardias (REVERT): a randomised controlled trial fulltext